FORM 3805A (05-04)
PIPING/MOUNTING:
The pump inlet and outlet has 3/4" pipe connections. Use
pipe sealant on the threads and other connections. The base
does not require direct mounting if one of the pipe flanges is
rigid mounted. Do not rigid mount both the flanges and the
base to avoid mounting tolerances that may distort the motor
b
ase. Install the pump with the shaft in a horizontal direction.
Never install the pump vertical with the motor below the
pump.
ELECTRICAL:
The motor must be protected from over current by using a
fuse or circuit breaker (see chart below for correct protection).
The proper minimum wire size is stated for each voltage
application. Make sure that the pump has the proper voltage
r
ating to match the installation power. Do not use or install if
the voltage on the label is different than the installation. All
wire connections must be secure and sealed to protect
arcing. Follow all local installation codes.
MOTOR VOLTAGE FUSE/CB WIRE SIZE
ON NAME PLATE AMPS AWG
12VDC 15 14
24VDC 10 16
32VDC 6 18
115VAC 2 18
230VAC 1 18
OPERATION:
The pump should be operated with liquid in the pump
otherwise seal damage may occur. If an inlet valve is present,
the valve should always be completely open during
operation to avoid cavitation. An outlet valve may be used to
throttle the flow rate. Avoid repeated starts and stops; the
pump can operate for a long period of time without any flow.
DC motors are brush type and may emit a noise from the
brush that can sound like a squeal, this is normal. The pump
will be extremely quiet unless there is air in the system.
REPAIR AND MAINTENANCE:
DC motor brush life expectancy is 6,000 hours total brush life.
The motor is not rebuildable after the brushes have worn to
the limits.
The pump has a carbon/ceramic seal that may last several
thousand hours based upon the application. If the motor is
replaced, the mechanical shaft seal should also be replaced.
A seal that leaks will show leakage thr
ough the slot between
the pump housing and the motor. Extreme leakage may
damage the motor bearings and contaminate the
inside of the motor.
DISASSEMBLY:
1. Remove three cover screws and remove the cover,
discarding the o-ring.
2. Secure the impeller and remove the impeller locknut.
Pull the impeller straight out off the motor shaft.
3. Remove the seal-rotating portion by pulling the seal off
b
y hand.
4. Remove the capscrews that hold the pump housing
onto the motor. Remove the pump housing and push the
seal seat out using a screwdriver.
INSPECT PUMP PARTS:
Always replace the mechanical seal. Check the seal for
dry run wear or damage. Check the motor shaft for wear
at the secondary sealing surface from the mechanical
s
eal. If worn, replace the motor. Check the motor bearings
by rotating the motor by hand. If the shaft rotation is
not smooth or has radial/axial endplay, replace the
motor. Check the impeller running surface between the
impeller and cover. If the surfaces are worn or
irregular, replace each item.
Clean the parts that are to be reused using a solvent or
mild cleaner. Remove abrasive material.
REASSEMBLY:
1. Press the new seal seat into the pump housing. A light
lubricant may be used to aid the assembly. Install the
pump housing onto the motor and fasten the screws
through the motor.
2. Install the rotating portion of the mechanical seal by
sliding the seal over the motor shaft. Do not use any
lubricant.
3. Place the impeller onto the shaft over the D drive
against the shoulder and tighten the impeller lock nut
until the impeller is securely shouldered on the motor
shaft. Thread locking grade Loctite should be used to
secure the nut.
4. Stretch the o-ring over the cover pilot. Install the cover
onto the housing and fasten the capscrews and
lockwashers.
Check the pump for internal interference by rotating the
impeller. The pump should rotate freely with only seal
friction.
ITEM QTY. PART NO. DESCRIPTION
1
1
34036
12VDC MOTOR
34293
24VDC MOTOR
34504 115VDC ODP
35178 115V
AC TENV
35179 230VAC TENV
2 2 34369 GROMMET
3 1 34032 HOUSING- 316 SS
4 1 34038 MECH SEAL- VITON
5 1 34033 IMPELLER- 316 SS
6
1
28766
ACORN NUT 316 SS
7
1 34040 O-RING- VITON
8 1 34035 COVER- 316 SS
9
3
33564 LOCKW
ASHER 316 SS
10
3
34037
1/4-20 CAPSCREW 316 SS
1
2
3
4
5
6
7
8
9
10