Mp-pumps HTO 120 INSTALL Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Pompes Mp-pumps HTO 120 INSTALL. MP Pumps HTO 120 INSTALL User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 4
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
FORM 3061-B
PRINTED IN U.S.A. (1-07)
MP PUMPS HTO SERIES
This bulletin must be read completely before installing, operating, or servicing the pump.
HTO 120 INSTALLATION AND SERVICE INSTRUCTIONS
WARNING:
If any of the items listed below are violated, serious injury or death from burns caused
by hot oil may occur.
DO NOT perform service or maintenance when
the pumping system is pressurized or hot -
serious injury or death from burns caused by hot
oil may occur.
DO NOT operate the pump in a manner that it
was not intended to be use.
DO NOT install for use in an open environment
where people are present.
DO NOT install in a rigid piping system that
does not allow the pipe to expand and cause the
pump to be strained.
DO NOT continue to operate the pumping
system when a known leak exists or the system
continues to smoke.
DO NOT continue to operate the pump when
unusual noise or vibration occurs.
DO NOT install or use near water where the
pumping system may come into contact with
water or is splashed by water.
DO NOT operate beyond the pressure or
temperature limits stated in the product
literature, see form 9050.
DO NOT allow severe temperature
changes to occur in a short time period
within the pumping system.
DO NOT mix dif
ferent types or grades of oil
within the oil system.
DO NOT use an oil that is not a
recommended heat transfer oil by the
manufacturer.
DO NOT exceed the maximum oil
temperature rated by the oil manufacturer
at the hottest point in the pumping system.
DO NOT mount the pump such that high
piping loads exist on the pump flanges.
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1 - FORM 3061-B

FORM 3061-BPRINTED IN U.S.A. (1-07)MP PUMPS HTO SERIESThis bulletin must be read completely before installing, operating, or servicing the pump.HTO

Page 2 - INSTALLATION AND START-UP

MP PUMPS HTO SERIESAPPLICATION AND INSTALLATION INSTRUCTIONSINSTALLATION1. The pump must be installed in a horizontal shaftposition.2. The housing m

Page 3 - OPERATION AND MAINTENANCE

MP PUMPS HTO SERIESOPERATION AND MAINTENANCEThermal oil vapors leaking from a system can behighly flammable.Any system leak should be repaired immed

Page 4

MP PUMPS HTO SERIESHTO 120 ASSEMBLY INSTRUCTIONSFORM 3061-BPRINTED IN U.S.A. (1-07)1. Assemble drive sleeve #11 (29781), impeller#1 (29770) and nut

Commentaires sur ces manuels